Drinking Water Metals Testing

Know What’s in
Your Water Before
You Drink It.

16 metals. EPA-approved ICP methods. NJ NELAP certified. Results accepted for SDWA, LCRR, and NJ drinking water compliance.

NJ NELAP TNI Accredited EPA 200.5 / 200.7 ICP Technology
Get Your Sample Kit → Contact Us
Regulatory context

Lead. Arsenic. Copper. 13 More.

The Safe Drinking Water Act sets enforceable limits for 16 metals IRIS tests in your water supply. NJ NELAP certified, TNI accredited — every result carries regulatory acceptance for SDWA, LCRR, and NJ drinking water standards.

NJ NELAP certified, TNI accredited. Every result carries the weight of regulatory acceptance — SDWA compliance, LCRR school tap testing, and NJ private well ordinances.
Parameter
Limit & Standard
Lead
15 µg/L — Action Level (LCRR)
Arsenic
10 µg/L — MCL (SDWA)
Copper
1.3 mg/L — Action Level (LCRR)
Chromium
100 µg/L — MCL (SDWA)
Cadmium
5 µg/L — MCL (SDWA)
Barium
2 mg/L — MCL (SDWA)
Selenium
50 µg/L — MCL (SDWA)
Antimony
6 µg/L — MCL (SDWA)

All 16 Parameters — EPA 200.5 & 200.7 (ICP)

Methods: EPA 200.5 · EPA 200.7 (ICP) · NJ NELAP · TNI

Aluminum
Antimony
Arsenic
Barium
Beryllium
Cadmium
Chromium
Copper
Iron
Lead
Manganese
Nickel
Selenium
Silver
Thallium
Zinc
Service menu

Three Testing Panels. One Accredited Lab.

Select the panel that matches your regulatory requirement and sample volume.

Primary
Metals Panel

EPA 200.5 · ICP — Axially Viewed

Analytes
16 metals
Best For
SDWA compliance monitoring · Private well screening · Municipal water system testing
Regulation
SDWA MCLs · NJ Drinking Water Standards
Turnaround
5–7 business days

Lead & Copper
Compliance

EPA 200.5 · ICP — Axially Viewed

Analytes
Lead + Copper
Best For
LCRR compliance · School & childcare tap testing · Residential service line verification
Regulation
LCRR AL: Pb 15 µg/L · Cu 1.3 mg/L
Turnaround
3–5 business days

Expanded
Metals Panel

EPA 200.7 · ICP

Analytes
Full suite
Best For
Comprehensive private well testing · Industrial water source screening · Full SDWA parameter list
Regulation
All SDWA metals MCLs · NJ private well ordinances
Turnaround
5–7 business days

Not sure which panel? Send us a message — we’ll match you to the right method and regulatory requirement.

Decision guide

Which Panel Is Right for Your Situation?

Match your regulatory requirement and sample type to the correct panel before you collect.

School or childcare facility tap testing — LCRR mandate LCRR requires all outlets tested in schools and childcare facilities; action level Pb 15 µg/L, Cu 1.3 mg/L.
Lead & Copper Panel
Private well — homeowner or new construction baseline NJ private well testing ordinances typically require full metals panel at property transfer or new construction.
Primary or Expanded Metals
Municipal water system — SDWA compliance monitoring EPA 200.5 ICP is the standard method for SDWA metals compliance reporting to NJ DEP.
Primary Metals Panel
Commercial or multi-family building — tenant water quality documentation Lead and copper are primary regulatory concerns in building plumbing; LCRR applies to buildings serving vulnerable populations.
Lead & Copper Panel
IH or consultant — full source water characterization or litigation support EPA 200.7 provides a broader parameter list for comprehensive water quality assessment.
Expanded Metals Panel

Questions about SDWA or LCRR sample collection requirements? Send us a message — one reply, right panel.

Field collection requirements

Metals Sampling Has Strict Protocols.

Container type and preservation errors invalidate results. IRIS provides everything you need in the kit.

DO
  • Lab-supplied, pre-cleaned HDPE or polyethylene bottles (250 mL minimum)
  • First-draw sample for LCRR — no flushing; water stagnant ≥6 hours
  • Preserved with HNO&sub3; to pH <2 at collection or by lab upon receipt
  • Cool to 4°C for shipment — hold time 6 months preserved
  • COC completed before shipment — include source type and flushing status
DO NOT
  • Glass containers — metals adsorb to glass, biasing results low
  • Pre-flushed sample for first-draw LCRR compliance testing
  • Unpreserved samples — acidification is required for metals stability
  • Tap water from kitchen filter — sample from cold tap, filter bypassed
  • Delay shipment — preservation and holding time are regulatory requirements

IRIS provides pre-cleaned, preserved HDPE bottles, COC forms, and pre-paid shipping labels with every kit.

Process

How It Works

From kit order to certified analytical report — four steps.

01

Order Your Kit

Select your panel. IRIS ships pre-cleaned HDPE bottles, HNO&sub3; preserved, COC form, and pre-paid FedEx label to your door.

Order Kit →
02

Collect & Complete COC

Sample per LCRR first-draw or flushed protocol depending on purpose. Complete COC with source type, address, and sample location.

03

Ship Overnight

Drop at any FedEx location. Pre-paid label included. Samples shipped at 4°C. Hold time 6 months preserved.

04

Certified Report

ICP analytical report with MCL comparisons. NJ NELAP certified. Format accepted for SDWA and LCRR compliance reporting.

Every kit includes: Pre-cleaned preserved HDPE bottles · COC form · Pre-paid overnight shipping label · Sampling guide

NJ NELAP · TNI Accredited · EPA 200.5 / 200.7 · SDWA · LCRR

Order Your Drinking
Water Testing Kit.

16 metals. ICP precision. Results accepted for SDWA, LCRR, and NJ DEP compliance.

Get Sample Kit → Submit a CoC

Kit includes:

Pre-cleaned HDPE bottles (HNO&sub3; preserved) COC form Pre-paid overnight shipping label Sampling guide